Assa Abloy Dragon
ASSA ABLOY Dragon — RC3 steel security door with EI30s and EI60s fire resistance. Made to measure, with an ASSA ABLOY ironmongery package for access-controlled openings.
RC3
EI30s EI60s
CE certified
Internally reinforced
Anti-corrosion coating
Abloy locks
Sound insulation
Resistance to wind load
Our doors are shipped worldwide on an FOB basis

Assa Abloy Dragon
The leaf is assembled from two cold-formed galvanised steel sheets of min. 1.0 mm, forming the door skins. The construction is stiffened with steel profiles and filled with mineral wool (60 kg/m³). All four edges have rebates with an EPDM gasket. The leaf is 60 mm thick. The hinge side is secured with three anti-burglary bolts. A 20 mm threshold is included as standard.
Typical applications include residential, storage, retail, garage and plant rooms with a medium burglary risk; military, police and other uniformed-service buildings specified to RC3; cash-handling premises; and energy or telecoms facilities that require a medium level of forced-entry resistance. The door is intended for medium-duty use.
Standard configuration: three Ø22 mm ball-bearing hinges welded to the leaf, with three anti-burglary bolts on the hinge side; ABLOY DC500 door closer with guide rail; ABLOY AHW500 stainless steel lever set; ABLOY EL567 multipoint electromechanical lock; two stainless steel 304 square-corner kicking plates (H150 × W900 mm); ABLOY EA219 6 m connector cable for electric locks; concealed mortice-fixing armoured door loop; and a Planet HS-FH + RD automatic drop seal.
Finishes: RAL powder coating or oak-veneered plywood panels (6 or 10 mm). Optional anti-burglary glazing (min. P5) can be supplied in custom shapes and layouts, with solid or glazed fanlights and side panels.
An additional lock is available as an option. Factory documentation is supplied with each doorset.
These doors are certified to EI30s and EI60s.
Our security doors are bespoke
The price fluctuates based on door sizes, project location, technical specifications, and specific customer preferences regarding integration with the access control system. These are just a few factors to consider. For a precise price estimate, please fill out the form below.
Request from Contractor - High Security Doors
Installation
Maximum 2500 characters
Related security doors:
High Security Doors · Fire Rated Security Door · Fire Escape Security Doors · Bank Designated Security Doors · All security doors · Knowledge base · Door hardware
Certification
Adherence to EN standards is expected in all commercial projects. Our security doors are tested and certified according to European Union norms.
- Fire Resistance
- According to EN 16034: 2014
- Burglar Resistance Classification
- Class RC3 according to EN 1627: 2012
- Wind load resistance
- Class C2 according to EN 12210:2016
- Water tightness
- Class 4A (outward opening) / class 3A (inward opening) according to EN 12208:2001
- Dangerous substances
- Not declared according to EN 14351-1+A2:2016
- Sound insulation
- Rw = 46 dB according to EN ISO 717-1:2013
- Thermal permeability
- Uw = 1.3 W/m²K according to EN ISO 10077-1:2017
- Air permeability
- Class 3 according to EN 12207:2017
- Operational forces
- Class 3 according to EN 12217:2015
- Mechanical strength
- Class 4 according to EN 1192:2001